Your Order Cart is empty.

10mm Linear Resonant Actuator - 4mm Type

Model
C10-100
Body Diameter Body Length Rated Voltage (RMS) Rated Resonant Frequency Typical Rated Operating Current Typical Norm. Amplitude
10 mm 3.65 mm 2 V RMS 175 Hz 69 mA 1.5 G

Physical Specification

Parameter Specification Condition
Body Diameter 10 mm Max body diameter or max face dimension where non-circular
Body Length 3.65 mm Excl. shafts, leads and terminals
Unit Weight 2 g

Leads & Connectors Specification

Parameter Specification Condition
Lead Length 100 mm Lead lengths defined as total length or between motor and connector
Lead Strip Length 1.5 mm
Lead Wire Gauge 32 AWG
Lead Configuration Straight

Operational Specification

Parameter Specification Condition
Rated Voltage (RMS) 2 V RMS
Rated Resonant Frequency 175 Hz At rated voltage with the inertial test load
Max. Rated Operating Current 90 mA At rated voltage using the inertial test load
Rated Inertial Test Load 100 g Mass of rated load standard test sled
Max. Start Voltage 0.4 V Certified starting voltage. Measured at no load, where applicable
Min. Vibration Amplitude 1 G Peak-to-peak value at rated voltage using the inertial test load
Max. Operating Voltage 2.05 V
Min. Insulation Resistance 1 MOhm At 50V DC between motor terminal and case

Typical Performance Characteristics

Parameter Specification Condition
Typical Rated Operating Current 69 mA At rated voltage using the inertial test load
Typical Vibration Amplitude 1.5 G Peak-to-peak value at rated voltage using the inertial test load
Typical Vibration Efficiency 10.8 G/W At rated voltage using the inertial test load
Typical Norm. Amplitude 1.5 G Peak-to-peak vibration amplitude normalised by the inertial test load at rated voltage
Typical Start Voltage 0.25 V Measured at no load, where applicable
Typical Terminal Resistance 27 Ohm
Typical Terminal Inductance 415 uH

Typical Haptic Characteristics

Parameter Specification Condition
Typical Lag Time 8 ms At rated voltage using the inertial test load
Typical Rise Time 63 ms At rated voltage using the inertial test load
Typical Stop Time 165 ms At rated voltage using the inertial test load

Environmental Characteristics

Parameter Specification Condition
Max. Operating Temp. 70 Deg.C
Min. Operating Temp. -25 Deg.C
Max. Storage & Transportation Temp. 85 Deg.C
Min. Storage & Transportation Temp. -40 Deg.C

Typical Packing Conditions

Parameter Specification Condition
Carton Type Boxed Trays

This porduct is EOL and should not be used for new projects or designs. Please contact us if you require a similar part for your project or design.

Currently Available Stock for Samples
88
Pricing for Sample Orders (GBP):
Qty Break Unit Price
1+ £6.50
10+ £6.26
20+ £6.04
50+ £5.48